Counter, Tablets, Pills, 12-Lane, 2-Head Fill, Cremer, CF-1230 #5554570

Counter, Tablets, Pills, 12-Lane, 2-Head Fill, Cremer, CF-1230 #5554570

Location:Los Angeles, CA

Available quantity:1

orCall +1 (415) 467-3400

Description

Used Cremer 1230 12-lane Tablet Counter, Model CF1230-S006, Serial 873200DA, 220/60/3, built 1993. The Cremer CF-1230 is a 12-channel linear tablet and capsule counter, counts any kind of tablet, hard or softgel capsule. Includes bulk hopper with gate, linear vibratory plates for optimal product separation, 12-channel detection unit, and (2) filling nozzles with dust collection port. Operational Manual included.


Specifications

Stock Number5554570
ManufacturerCremer
ModelCF-1230
Year1993
Number of Lanes12-Lane
Fill NozzlesDual Head
TypeLinear Tablet Counter & Filler
Previous UseCounting and Filling of Supplements Tablets
BasisFOB

Additional Information

Specifications:

Counter: Count Value
Precount: Count value -30 (Max:100)
Start Seperation Speed: Count value -30
Counting speed: See how produvt reacts on plate(front)
Separations Speed: Counting speed -10
Hopper: 90
Hopper Frequency: Adjust it so it will not overfill the front plate
Hopping time: Value between 4 and 6
Rejection/min: 2
Nozzle vibration: 0, No vibration 4: vibration
Counting Mode: 0 counts higher than 10, 1: count lower than 10
Count Sensor delay: Set at 0, unless machine is doing undercounts(rotating Products)